KaRa hardware manual

Introduction

When timing races with KaRa you have two options:

  1. do the timing manually using the clock of the computer
  2. use an external dedicated clock (which can be activated manually or automatically)

1. Timing manually using the clock of the computer

The advantage here is obviously that you only need a computer. So there is no other hardware required and no connections to make.

The disadvantage is that your timing will not be very correct, because:

The procedure is simple: when a function key (<F1> ... <F12>) is pressed the current clock time will become available in the KaRa interface.

This method is usefull when the timing you require does not need to be reliable up to a hundreth of a second; e.g. in marathon races where the positions of the competitors are what it is about. Or you may want to resort to this setup if the outdoor circumstances are much too difficult to transport or maintain more than a laptop.

2. Use an external dedicated clock

The advantages are that the timing can be correct because:

Obviously if you operate the timing trigger manually this advantage is less important than if you use an automatically triggered system.

The disadvantage is that apart from a computer you will also need the dedicated external clock, for which you will need to supply 12V DC and which you will have to connect to your computer.
Also, you will need a trigger mechanism (automatic or manually) which will have to be connected to the chrono.

If timing is essential this is the setup you should use.

The remainder of this manual will explain the procedure for installing the external chrono.

Overview

photo chrono
  1. a triggering event from the finish and/or start short-cicuits one of the input lines of the chrono
    in the image you can see a black and a grey cable as wel as a red/black pair of wires leading to the chrono, these can all be connected to triggering devices

  2. the chrono registers the exact time

  3. the computer interrogates the chrono at regular intervals (every 1.5 seconds) and receives the registered times from the chrono, via the serial cable

Installing the external chrono

Because you are dealing with fragile equipment it is a good suggestion to fix the chrono and its accesories in a box. It avoids damage and water.

photo chrono For the chrono to work it must be fed with a 12V DC electrical current. A setup which has been used with good effect many times is shown here.
  1. either use 220V AC from the electricity network

  2. or else use a convertor 220V AC -> 12V DC to feed the chrono
Tips:
  • instead of starting from 220V AC from the electricity network, you could use a 12V battery (or the cigar-lighter of a car) this allows you greater independance outdoor)
    off course you will then also need a convertor 12V DC -> 220V AC

  • use a multiple-outlet 220V AC connector: thus other devices like the computer and a printer can be fed

The chrono in detail

photo chrono

The orange input connector

Before anything else you should connect your triggering device(s) to the orange input connector.
You can connect four different input lines to it.

Description of the pinns, top to bottom in the image:
1-4: 4 input data channels (3-0)
5: gnd
6: +5V (4.5V battery input is allowed)
7: gnd
8: +12V
So e.g. to connect a button to manually trigger an event you could connect it to the pinns 5 (gnd) and 1 (input channel 0).

The orange input connector can be disconnected from the chrono, which can be usefull because thus you can leave your triggering devices connected to it and you do not need to unscrew the wiring every time.

What's on the chrono PCB?

Some technical details:
Precision: 0.01 sec (so times are correct up to one hundredth of a second)
Debouncing: 0.03 sec (triggering events need at least 3 hundredths of a second between them to be accepted)
Buffer: 11 event times (interrogating the chrono every 1.5 seconds works fine)
24 MHz processor
128 bytes RAM
2 Kb ROM

Once the 12V DC is on, the green led should show a heartbeat. This confirms that the chrono processor is up and working fine.
If one of the four input data channels receives a signal (a data channel is low) then the red led lights up. This gives you a visual confirmation of the event.
The reset button should normally never be used. It is there only to overcome a system panic.

Step by step

To sum it all up, here is a cookbook recipe to install the system: